Essential Requirements (ER): Refer to the Necessary Requirements for the G3 Fax Machine MTCTE Certification
The G3 Fax Machine was covered by the Mandatory Testing and Certification of Telecom Equipment (MTCTE) scheme under the aegis of the Department of Telecommunications (DoT), Government of India. All Fax Machines (G3) manufactured in India and imported and sold in India are required to comply with the notified essential requirements (ER) prescribed under ES No. TEC13292407.
These requirements will be in effect from 1st July 2024 and will cover the standalone G3 fax machines.
Essential Requirements for G3 Fax Machine
The notified ER contains two product variants
- Support of fax machines (G3) and handsets via HTTP/HTTPS.
- G3 Fax Machine w/o Handset
For the G3 Fax Machine MTCTE certification, each variant has to be tested on the relevant technical criteria. The certification guarantees safety, performance, and network standards of the equipment in India.
Key Technical Parameters G3 Fax Machine
- Acoustic shock absorption (For handset models)
- Conducted and radiated emissions (EMC)
- Electrostatic Discharge Immunity (ESD)
- Tolerant of voltage fluctuations, surges, and electrical fast transients.
- The ability to withstand both radiated and conducted RF interference.
- Requirements for safe operation of IT equipment.
- Over-voltage and overcurrent protection.
- Fax receiver sensitivity
- Fax transmit power
The 2-wire interface also undergoes several tests to ensure network compatibility, including idle state current, insulation testing, longitudinal conversion loss, maximum loop current, and return loss.
Why MTCTE Compliance Is Important for a G3 Fax Machine
1. Variant 1 : FAX machine with handset
1.1 Parameters Linked with Product Variant
| S.No. | Parameter Name | Standard Name |
| 1.1.1 | Acoustic Shock Absorption | P.360. Annex-D |
| 1.1.2 | Conducted And Radiated Emission - Class B | TEC EMI EMC Standard CISPR 32 EN55032. Annex-B |
| 1.1.3 | Immunity to AC Voltage Dips and Short Interruptions | TEC EMI EMC Standard EN/IEC:61000-4-11. Annex-B |
| 1.1.4 | Immunity to DC Voltage Dips and Short Interruptions | EN/IEC:61000-4-29. Annex-B |
| 1.1.5 | Immunity to Electrostatic Discharge | TEC EMI EMC Standard EN/IEC:61000-4-2.Annex-B |
| 1.1.6 | Immunity to Fast Transients (Burst) | TEC EMI EMC Standard EN/IEC:61000-4-4.Annex-B |
| 1.1.7 | Immunity to Radiated RF | TEC EMI EMC Standard EN/IEC:61000-4-3.Annex-B |
| 1.1.8 | Immunity to RF Field Induced Conducted Disturbance | TEC EMI EMC Standard EN/IEC:61000-4-6.Annex-B |
| 1.1.9 | Immunity to Surges | TEC EMI EMC Standard EN/IEC:61000-4-5.Annex-B |
| 1.1.10 | IT Equipment Safety | IS 13252-1 or IEC:60950-1 or IEC 62368-1.Annex-A1 |
| 1.1.11 | Over Voltage and over Current Protection on 2W | K.21. Annex-D |
| 1.1.12 | Receiver Sensitivity for FAX | T.4. Annex-D |
| 1.1.13 | Transmit Power Fax Machine | T.4. Annex-D |
1.2 Interface 1 : 2 Wire
| S.No. | Parameter Name | Standard Name |
| 1.2.1 | Idle State Current for 2 wire Int | ETSI EN 300 001 ETSI TBR-21 Cl. 4.4.1. Annex-D |
| 1.2.2 | Insulation Test for 2 wire Int | ETSI EN 300 001. Annex-D |
| 1.2.3 | Longitudinal Conversion Loss for 2W Int | Q.552 Cl. 2.2.2. Annex-D |
| 1.2.4 | Maximum Loop Current for 2W Int | ETSI EN 300 001 ETSI TBR-21 Cl.4.4.3. Annex-D |
| 1.2.5 | Return Loss for 2W Int | Q.552 Cl. 2.2.1.2. Annex-D |
2. Variant 2 : FAX machine without handset
2.1 Parameters Linked with Product Variant
| S.No. | Parameter Name | Standard Name |
| 2.1.1 | Conducted And Radiated Emission - Class B | TEC EMI EMC Standard CISPR 32 EN55032. Annex-B |
| 2.1.2 | Immunity to AC Voltage Dips and Short Interruptions | TEC EMI EMC Standard EN/IEC:61000-4- 11. Annex-B |
| 2.1.3 | Immunity to DC Voltage Dips and Short Interruptions | EN/IEC:61000-4-29. Annex-B |
| 2.1.4 | Immunity to Electrostatic Discharge | TEC EMI EMC Standard EN/IEC:61000-4-2. |
| Annex-B | ||
| 2.1.5 | Immunity to Fast Transients (Burst) | TEC EMI EMC Standard EN/IEC:61000-4-4. Annex-B |
| 2.1.6 | Immunity to Radiated RF | TEC EMI EMC Standard EN/IEC:61000-4-3. Annex-B |
| 2.1.7 | Immunity to RF Field Induced Conducted Disturbance | TEC EMI EMC Standard EN/IEC:61000-4-6. Annex-B |
| 2.1.8 | Immunity to Surges | TEC EMI EMC Standard EN/IEC:61000-4-5. Annex-B |
| 2.1.9 | IT Equipment Safety | IS 13252-1 or IEC:60950-1 or IEC 62368-1. Annex-A1 |
| 2.1.10 | Overvoltage and overcurrent protection on 2W | K.21. Annex-D |
| 2.1.11 | Receiver Sensitivity for FAX | T.4. Annex-D |
| 2.1.12 | Transmit Power Fax Machine | T.4. Annex-D |
2.2 Interface 1: 2-Wire
| S.No. | Parameter Name | Standard Name |
| S.No. | Parameter Name | Standard Name |
| 2.2.1 | 2-wire | 2-wire |
| 2.2.2 | Insulation Test for 2-wire Int | ETSI EN 300 001. Annex-D |
| 2.2.3 | Longitudinal Conversion Loss for 2W Int | Q.552 Cl. 2.2.2. Annex-D |
| 2.2.4 | Maximum Loop Current for 2W Int | ETSI EN 300 001 ETSI TBR-21 Cl.4.4.3. Annex-D |
| 2.2.5 | Return Loss for 2W Int | Q.552 Cl. 2.2.1.2. Annex-D |
Why Choose UMSPCS?
UMSPCS offers complete assistance for G3 Fax Machine MTCTE certification, including the following:
Identify the requirements from the set of essential requirements that are relevant for the situation.
- Conducting a review of documentation and compliance support.
- Ensure that the tests are coordinated with accredited testing laboratories.
- Test report verification
- Filling out an application via MTCTE.
- Support for end-to-end certification until approval.
Whether you are a manufacturer, an importer, or a brand owner, our compliance experts can guide you through the certification process, making it easier and less risky for you and saving you time.
Conclusion
The first step in getting a G3 Fax Machine MTCTE certification is to meet ER No. TEC13292407. The understanding of required tests and the availability of required documentation ensures a seamless certification process and expedites market entry. UMSPCS possesses the expertise and help needed to ensure that businesses can become MTCTE compliant in a timely and effective way.
Frequently Asked Questions (FAQs)
Yes, G3 Fax Machines need to meet MTCTE essential requirements for importation and sale in India.
G3 Fax Machines is an MTCTE (Minutewomen's Taxpayer Education Center) registered company under No. ER No. TEC13292407.
Standalone G3 fax machines (with and without a handset) use the ER.
Tests include equipment safety, EMC, RF immunity, electrical protection, fax performance, and 2-wire interface requirements.
Absolutely, all imported G3 fax machines should be MTCTE certified for sale in India.
UMSPCS will provide full support in documentation, testing coordination, portal filing, and certification assistance.
The essential requirements for G3 fax machines were updated on 1 July 2024.
Ready to get your electronics BIS-registered?
❓ Ask a Question
Services we Offer
- BIS ISI Mark for foreign manufacturers
- BIS CRS Registration for electronic products
- Domestic product certification (ISI Mark)
- WPC-ETA approval
- BIS Scheme X certification
- BEE certification
- Legal metrology
- Cosmetics Registration (CDSCO)
- ROHS License
- Trade mark registration
- FSSAI certification
- Drug License
- GEM Registration
- Copyright Registration
- ISO Certification
- MSME / SSI / UDYAM Registration
- E-waste management (EPR)
- NSIC Registration
- Plastic waste management
- IMEI Registration
- TEC/MTCTE approval
- NOC for steel
- Import / Export License
- IP Rating Test
- RF Test (WPC)
- EMC Test – TEC