Essential Requirements (ER): Refer to the Necessary Requirements for the G3 Fax Machine MTCTE Certification

The G3 Fax Machine was covered by the Mandatory Testing and Certification of Telecom Equipment (MTCTE) scheme under the aegis of the Department of Telecommunications (DoT), Government of India. All Fax Machines (G3) manufactured in India and imported and sold in India are required to comply with the notified essential requirements (ER) prescribed under ES No. TEC13292407.

These requirements will be in effect from 1st July 2024 and will cover the standalone G3 fax machines.

Essential Requirements for G3 Fax Machine

The notified ER contains two product variants

  • Support of fax machines (G3) and handsets via HTTP/HTTPS.
  • G3 Fax Machine w/o Handset

For the G3 Fax Machine MTCTE certification, each variant has to be tested on the relevant technical criteria. The certification guarantees safety, performance, and network standards of the equipment in India.

Key Technical Parameters G3 Fax Machine

The essential requirements set out that tests shall be performed on several critical parameters, including:
  • Acoustic shock absorption (For handset models)
  • Conducted and radiated emissions (EMC)
  • Electrostatic Discharge Immunity (ESD)
  • Tolerant of voltage fluctuations, surges, and electrical fast transients.
  • The ability to withstand both radiated and conducted RF interference.
  • Requirements for safe operation of IT equipment.
  • Over-voltage and overcurrent protection.
  • Fax receiver sensitivity
  • Fax transmit power

The 2-wire interface also undergoes several tests to ensure network compatibility, including idle state current, insulation testing, longitudinal conversion loss, maximum loop current, and return loss.

Why MTCTE Compliance Is Important for a G3 Fax Machine

The notified essential requirements are mandatory to be met for acquiring MTCTE certification. The right ER and the right testing place are essential to avoid application rejection and additional testing costs, certification delays, and market entry issues. The product's conformance with the above-mentioned DoT safety, electromagnetic compatibility, and telecom network performance standards is also another significant compliance parameter. Also get to know more information about 5G Core Under MTCTE Certification in India.

1.    Variant 1 : FAX machine with handset

1.1  Parameters Linked with Product Variant
S.No.Parameter NameStandard Name
1.1.1Acoustic Shock AbsorptionP.360. Annex-D
1.1.2Conducted And Radiated Emission - Class BTEC EMI EMC Standard CISPR 32 EN55032. Annex-B
1.1.3Immunity to AC Voltage Dips and Short InterruptionsTEC EMI EMC Standard EN/IEC:61000-4-11. Annex-B
1.1.4Immunity to DC Voltage Dips and Short InterruptionsEN/IEC:61000-4-29. Annex-B
1.1.5Immunity to Electrostatic DischargeTEC EMI EMC Standard EN/IEC:61000-4-2.Annex-B
1.1.6Immunity to Fast Transients (Burst)TEC EMI EMC Standard EN/IEC:61000-4-4.Annex-B
1.1.7Immunity to Radiated RFTEC EMI EMC Standard EN/IEC:61000-4-3.Annex-B
1.1.8Immunity to RF Field Induced Conducted DisturbanceTEC EMI EMC Standard EN/IEC:61000-4-6.Annex-B
1.1.9Immunity to SurgesTEC EMI EMC Standard EN/IEC:61000-4-5.Annex-B
1.1.10IT Equipment SafetyIS 13252-1 or IEC:60950-1 or IEC 62368-1.Annex-A1
1.1.11Over Voltage and over Current Protection on 2WK.21. Annex-D
1.1.12Receiver Sensitivity for FAXT.4. Annex-D
1.1.13Transmit Power Fax MachineT.4. Annex-D

1.2  Interface 1 : 2 Wire

S.No.Parameter NameStandard Name
1.2.1Idle State Current for 2 wire Int

ETSI EN 300 001 ETSI TBR-21 Cl. 4.4.1.

Annex-D

1.2.2Insulation Test for 2 wire IntETSI EN 300 001. Annex-D
1.2.3Longitudinal Conversion Loss for 2W IntQ.552 Cl. 2.2.2. Annex-D
1.2.4Maximum Loop Current for 2W Int

ETSI EN 300 001 ETSI TBR-21 Cl.4.4.3.

Annex-D

1.2.5Return Loss for 2W IntQ.552 Cl. 2.2.1.2. Annex-D

2.    Variant 2 : FAX machine without handset

2.1  Parameters Linked with Product Variant
S.No.Parameter NameStandard Name
2.1.1Conducted And Radiated Emission - Class BTEC EMI EMC Standard CISPR 32 EN55032. Annex-B
2.1.2Immunity to AC Voltage Dips and Short Interruptions

TEC EMI EMC Standard EN/IEC:61000-4-

11. Annex-B

2.1.3Immunity to DC Voltage Dips and Short InterruptionsEN/IEC:61000-4-29. Annex-B
2.1.4Immunity to Electrostatic DischargeTEC EMI EMC Standard EN/IEC:61000-4-2.
  Annex-B
2.1.5Immunity to Fast Transients (Burst)

TEC EMI EMC Standard EN/IEC:61000-4-4.

Annex-B

2.1.6Immunity to Radiated RF

TEC EMI EMC Standard EN/IEC:61000-4-3.

Annex-B

2.1.7Immunity to RF Field Induced Conducted Disturbance

TEC EMI EMC Standard EN/IEC:61000-4-6.

Annex-B

2.1.8Immunity to Surges

TEC EMI EMC Standard EN/IEC:61000-4-5.

Annex-B

2.1.9IT Equipment Safety

IS 13252-1 or IEC:60950-1 or IEC 62368-1.

Annex-A1

2.1.10Overvoltage and overcurrent protection on 2WK.21. Annex-D
2.1.11Receiver Sensitivity for FAXT.4. Annex-D
2.1.12Transmit Power Fax MachineT.4. Annex-D
2.2  Interface 1: 2-Wire
S.No.Parameter NameStandard Name
S.No.Parameter NameStandard Name
2.2.12-wire2-wire
2.2.2Insulation Test for 2-wire IntETSI EN 300 001. Annex-D
2.2.3Longitudinal Conversion Loss for 2W IntQ.552 Cl. 2.2.2. Annex-D
2.2.4Maximum Loop Current for 2W Int

ETSI EN 300 001 ETSI TBR-21 Cl.4.4.3.

Annex-D

2.2.5Return Loss for 2W IntQ.552 Cl. 2.2.1.2. Annex-D

Why Choose UMSPCS?

UMSPCS offers complete assistance for G3 Fax Machine MTCTE certification, including the following:

 Identify the requirements from the set of essential requirements that are relevant for the situation.

  • Conducting a review of documentation and compliance support.
  • Ensure that the tests are coordinated with accredited testing laboratories.
  • Test report verification
  • Filling out an application via MTCTE.
  • Support for end-to-end certification until approval.

Whether you are a manufacturer, an importer, or a brand owner, our compliance experts can guide you through the certification process, making it easier and less risky for you and saving you time.

Conclusion

The first step in getting a G3 Fax Machine MTCTE certification is to meet ER No. TEC13292407. The understanding of required tests and the availability of required documentation ensures a seamless certification process and expedites market entry. UMSPCS possesses the expertise and help needed to ensure that businesses can become MTCTE compliant in a timely and effective way.

Frequently Asked Questions (FAQs)

 

Yes, G3 Fax Machines need to meet MTCTE essential requirements for importation and sale in India.

 

G3 Fax Machines is an MTCTE (Minutewomen's Taxpayer Education Center) registered company under No. ER No. TEC13292407.

 

Standalone G3 fax machines (with and without a handset) use the ER.

 

Tests include equipment safety, EMC, RF immunity, electrical protection, fax performance, and 2-wire interface requirements.

 

Absolutely, all imported G3 fax machines should be MTCTE certified for sale in India.

UMSPCS will provide full support in documentation, testing coordination, portal filing, and certification assistance.

 

 

The essential requirements for G3 fax machines were updated on 1 July 2024.

Bis certification

Ready to get your electronics BIS-registered?

❓ Ask a Question

Service & blog Page Form
ISO Badge
Contact Page Form