Get BIS CRS certification for nickel-cadmium cells and batteries under IS 16046 (Part 1): 2018. UMSPCS assists with product testing, documentation and BIS registration in India.
BIS CRS Certification for Nickel System Cells and Batteries Part 1
BIS CRS Certification for Nickel System Cells and Batteries Part 1
- BIS Registration Guidance
- Application Filing Support
- BIS Authority Coordination
- Cost & Timeline Clarity
- Complete Documentation Help

Enter your details to receive a full quote and consultation
BIS CRS Certification for Nickel System Cells & Batteries - IS 16046 (Part 1): 2018
Many everyday items, from handheld electronics and portable equipment to other battery-powered items, are operated by portable rechargeable batteries. The fabrication, charging characteristics, insulation, and terminal and/or protection against reasonable misuse of cells and batteries are significant for their safety.
For manufacturing, importing and sales of covered products, BIS CRS Certification for Nickel System Cells & Batteries under IS 16046 (Part 1):2018 is essential. The official product list published by CRS specifies that the product Sealed Secondary Cells/Batteries containing alkaline or other non-acid electrolytes for portable applications- Part 1 Nickel Systems was added to the list with effect from 1st June 2016 under IS 16046 (Part 1):2018.
UMSPCS offers you an entire range of services that cover everything, from the product assessment to the identification of standards, the choice of a laboratory for samples, the writing of the technical documentation, the filing of the application to the BIS and support in the registration process.
What Is BIS CRS Certification for Nickel System Batteries?
BIS CRS Certification for Nickel System Cells & Batteries is the registration that is required for the Covered portable sealed secondary cells and batteries conforming to IS 16046 (Part 1):2018.
This standard adopts the requirement of IEC 62133-1:2017 and applies to the safety requirement of portable sealed secondary cells and batteries assembled with nickel systems. The standard is listed as active by BIS.
IS 16046 consists of two parts:
- Part 1 – Nickel Systems
- Part 2 – Lithium Systems
As such, manufacturers don't recommend replacing Part 1 with Part 2 or vice versa. A nickel-system product needs to be assessed against the applicable Part 1 requirements.

Get Your Free Expert Consultation
Is BIS Registration Mandatory for Nickel System Cells & Batteries?
Yes. The official BIS product database has an explicit listing of these sealed secondary cells and batteries under the Compulsory Registration Scheme.
The BIS Scheme-II page also mentions IS 16046 for sealed secondary cells/batteries with alkaline or other non-acid electrolyte for portable use.
For businesses having dealings with the covered products, it is advisable to get the relevant BIS registration prior to introducing the products in the Indian market.
Which Nickel System Cells and Batteries Are Covered?
IS 16046 (Part 1):2018 is related to Portable sealed secondary nickel-system cells and batteries.
Rechargeable chemistries can be used in nickel-system products and include:
- Nickel-metal hydride (NiMH)
- Nickel-cadmium (NiCd)
The applicability of the product, however, should be verified according to the corresponding actual cell chemistry, construction, configuration and intended portable application and not just on the basis of the commercial name of the product.
It is necessary since the lithium system cells and batteries are not subject to IS 16046 (Part 1) but rather to IS 16046 (Part 2):2018.
What Safety Requirements Are Covered under IS 16046 (Part 1):
The standard covers a number of areas of cell and battery safety.
Key areas include:
- General safety considerations
- Insulation and wiring
- Venting
- Temperature, voltage and current control.
- Terminal contacts
- The process of putting cells together to form batteries
- Quality plan
- Battery safety components
- Charging procedures
- Intended use
- Reasonably foreseeable misuse
- Safety information
- The method of marking cells/batteries.
- Packaging
The requirements are also contained in the official test-report format and the scope of laboratory testing of BIS.
What Testing Is Required for BIS CRS Registration?
Product testing is an essential part of the BIS CRS registration.
Evaluation can be performed on topics including:
General Safety
The suitability of the construction and safety of the cell or battery is evaluated.
Insulation and Wiring
The electrical insulation and wiring are checked to meet the requirements.
Venting
The product is tested for suitable venting and safety measures.
Temperature, Voltage and Current Management
The safety operating conditions and charging conditions are assessed and are compliant with the standard.
Terminal Contacts
The safety requirements associated with the construction of the terminals and contact are evaluated.
Charging & Foreseeable Misuse
Specified charging procedures are included in the test programme, as are intended use and reasonably foreseeable misuse requirements. Currently these are defined as testing areas for IS 16046 (Part 1):2018 in BIS LIMS.
Marking, Safety Information & Packaging
Also included in the applicable assessment is the marking of cells/batteries and safety information and packaging requirements.
Specific tests and samples required are dependent on product configuration and applicable laboratory scope.
Who Needs BIS CRS Registration for Nickel Batteries?
Compliance with BIS CRS can be applicable to:
- Indian manufacturers
- Foreign manufacturers
- Importers
- Brand owners
- OEM/ODM manufacturers
- Battery manufacturers supplying portable applications
- Businesses introducing nickel-system rechargeable products in India
Foreign manufacturers must also take note of the need for an Authorised Indian Representative (AIR) to consider for a CRS application.
BIS CRS Registration Process for IS 16046 (Part 1)
Step 1: Product Profiling & IS Standards Identification
This eliminates:
Step 2 Involves Product Testing & Laboratory Coordination.
This entails:
Step 3: Document Preparation
The following is included in the documentation:
Step 4: BIS Application Filing
The steps taken here are as follows:
Step 5: Issue of BIS Registration
Step 6: Product marking & labelling compliance.
Steps include:
Step 7: Renewal & Ongoing Compliance Support
Assistance includes:
Documents Required for BIS CRS Registration IS 16046
Some typical documents that are necessary are as follows:
- An official document proving your company's registration is called a business registration certificate.
- Product specification: The product's specifications
- Test Reports: Laboratory accredited by BIS for demonstrating compliance.
- A document attesting to the ownership of your trademark, if any
- Letter of Authorisation: To give signatories or representatives permission
- AIR documents are only required if you choose to have an authorised Indian representative for your company from another country.
Costing & Timeline of BIS CRS Certification
The following variables affect certification costs:
- Product type
- The quantity of different model types
- Testing specifications
- Documentation requirements
- Fees that the government imposes
| Category | Total Cost (Excluding GST) |
|---|---|
| Indian Manufacturer | ₹55,000 + GST |
| Overseas Client | ₹90,000 + GST |
The true cost will depend on the product’s scope and testing needs.
Activity | Estimated Timeline |
Documentation Preparation | 5-7 Days |
Product Testing | 10-15 Days |
BIS Review & Approval | 7-10 Days |
Depending on how well the testing and documentation go, registration typically takes 20 to 30 days.
Why Do BIS CRS Applications for Nickel Batteries Get Delayed?
Common issues include:
- Incorrect standard identification
- Mixing up Part 1 and Part 2
- Product or chemistry information incorrect
- Incomplete technical documentation
- Test failures
- There are two types of differences: tested versus declared models.
- Missing manufacturer information
- Incorrect marking information
- Late answers for BIS question(s)
By the time the product is ready for testing and submission to the end-user, these problems may already have been identified through the early product evaluation.
How Can UMSPCS Help With BIS CRS Certification for IS 16046?
UMSPCS offers complete service for Nickel System Cells & Batteries Certification for IS 16046 (Part 1):2018. We provide complete services for BIS CRS Certification for Nickel System Cells & Batteries, including coordination of product assessment and testing, documentation, application submission, and factory inspection readiness.
Our support includes:
- Product applicability assessment
- IS 16046 Part 1 identification
- Laboratory coordination
- Testing support
- Technical documentation
- BIS CRS application filing
- Query handling
- 6 years of experience in this industry.
- Over 600 certificates have been successfully issued to manufacturers.
- Registration support
- Product/model addition assistance
- Post-registration guidance
Our objective is to make the BIS CRS process more structured and easier for manufacturers and businesses to manage.
Conclusion
BIS CRS Certification for Nickel System Cells & Batteries (IS 16046:2018) is one of the foremost compliance requirements for portable rechargeable battery products covered with sealed nickel cells and batteries in India.
The standard focuses on safety areas, including insulation, venting, temperature/current management, charging, foreseeable misuse, marking, safety information, and packaging.
Before applying for CRS, manufacturers need to verify the chemistry of the battery and scope of the product, ensure it meets the right standard, undergo testing at a laboratory recognised by the BIS, and provide consistent documentation.
Looking for BIS CRS Certification for Nickel System Cells & Batteries?
UMSPCS can help you with product evaluation, laboratory coordination, testing, documentation, BIS Application Form filling and CRS (Co-ordinated Registration Support).
Contact UMSPCS to discuss your IS 16046 (Part 1):2018 compliance requirements.
Also, need to get more information about BIS Certification for Solar Power Converters
Frequently Asked Questions (FAQs)
Yes, covered sealed secondary nickel system cells and batteries come under the scope of the BIS Compulsory Registration Scheme.
Covered nickel system portable cells and batteries are covered under IS 16046 (Part 1):2018.
No, separate IS 16046 (Part 2):2018 covers lithium system cells and batteries.
It varies from case to case, depending on testing of products, availability of documents and evaluation by BIS.
Yes, UMSPCS can help foreign battery manufacturers with testing and other requirements for BIS registration and AIRs.
Ready to get your electronics BIS-registered?
❓ Ask a Question
Services we Offer
- BIS ISI Mark for foreign manufacturers
- BIS CRS Registration for electronic products
- Domestic product certification (ISI Mark)
- WPC-ETA approval
- BIS Scheme X certification
- BEE certification
- Legal metrology
- Cosmetics Registration (CDSCO)
- ROHS License
- Trade mark registration
- FSSAI certification
- Drug License
- GEM Registration
- Copyright Registration
- ISO Certification
- MSME / SSI / UDYAM Registration
- E-waste management (EPR)
- NSIC Registration
- Plastic waste management
- IMEI Registration
- TEC/MTCTE approval
- NOC for steel
- Import / Export License
- IP Rating Test
- RF Test (WPC)
- EMC Test – TEC